ABBREVIATIONS, PREFIXES, AND LETTER SYMBOLS

Karl Fischer Reagent Method (ASTM D-1744-64)

The standard laboratory test to measure the water content of mineral base fluids. In this method, water reacts quantitatively with the Karl Fischer reagent. This reagent is a mixture of iodine, sulphur dioxide, pyridine, and methanol. When excess iodine exists, electric current can pass between two platinum electrodes or plates. The water in the sample reacts with the iodine. When the water is no longer free to react with iodine, an excess of iodine depolarises the electrodes, signalling the end of the test.

Kinematic viscosity

The time required for a fixed amount of oil to flow through a capillary tube under the force of gravity. The unit of kinematic viscosity is the stoke or centistoke (1/100 of a stoke). Kinematic viscosity may be defined as the quotient of the absolute viscosity in centipoises divided by the specific gravity of a fluid, both at the same temperature?

 



 